Part Number |
Input Volts |
Output Volts |
Road |
Max
Power |
Regulation |
Ripple P/P
(PARD) |
| |
| |
GPLV2612120 |
90~264 Vac |
12Vdc |
10A |
120W |
± 5% |
120mV |
| |
GPLV2615120 |
90~264 Vac |
15Vdc |
8A |
120W |
± 5% |
150mV |
| |
GPLV2616120 |
90~264 Vac |
16Vdc |
7.5A |
120W |
± 5% |
200mV |
| |
GPLV2624120 |
90~264 Vac |
24Vdc |
5A |
120W |
± 5% |
240mV |
| |
GPLV2635120 |
90~264 Vac |
35Vdc |
3.43A |
120W |
± 5% |
350mV |
| |
GPLV2648120 |
90~264 Vac |
48Vdc |
2.5A |
120W |
± 5% |
480mV |
| |
GPLV2675120 |
90~264 Vac |
75Vdc |
1.6A |
120W |
± 5% |
750mV |
|
|
|
|
|
|
|
|
|
|
| |
Special Features |
|
Environment |
| |
● Universal Input Voltage range |
|
● Operating Temperature : -10°
to 50℃ |
| |
● High Efficiency and
Reliability |
|
● Storage Temperature : -20° to
80℃ |
| |
● Small size and low profile |
|
● Operating Humidity : 20% to
80% RH |
| |
● Waterproof IP67 |
|
● Storage Humidity : 5% to 95%
RH |
| |
● High power density |
|
|
| |
● Low lose in empty load |
|
|
| |
● Low output ripple |
|
|
| |
● MTBF demonstrated: >50,000
hours |
|
|
| |
● Dimension: 153*70*47.5mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Electrical Specs |
|
|
|
|
|
| |
Input |
Output |
| |
●
Input voltage : 90~264 VAC |
●
Maximum power : 120W max |
| |
●
Frequency : 47-63 Hz |
● Hold Up Time : ≥10 msec
240Vac input voltage |
| |
● Input Current : 2A @Vin90Vac
full load |
● Overload protection :
≤110~150%@ all input voltage |
| |
●
Inrush Current : 80A @Vin240Vac, Cold start at 25℃ |
● Over shoot : ≤10% of normal
voltage value. |
| |
● Efficiency : 87% min |
● SCP : short circuited
protection and with auto- recovery function |
| |
● Leakage Current : <3.5mA @
50/60 Hz. |
|
|
|
|
|
|
|
|
|
|
|
| |
Safety |
|
|
|
|
|
|
|
| |
● Meet UL1310 |
|
|
|
|
|
|
|
| |
● Meet
CE (EN61347) |
|
|
|
|
|
|
|
| |
● EMC standard: EN55022 and FCC
part 15 (class B) |
|
|
|
|